• DESCRIPTION
  • SPECIFICATIONS
  • CYLINDER CONNECTIONS
  • ASSEMBLE YOUR MAJORPLUS
  • SPARE PARTS
  • The body and cover are machined directly from brass bar and are nickel-plated.
  • The safety valve is sealed to the pressure calibration with an anti-tampering system.
  • Available in the left side connection version or with the 1 station version which also includes a rear connection.
  • Front adjustment system.
  • The high-pressure capsule is entirely made of brass with a tapered PTFE tablet.
  • Pressure vent created by means of a safety valve ring.
  • Provided with a sintered bronze dual-protection filter: one on the cylinder connection injector (which can be inspected for cleaning) and the second inside the high-pressure capsule.
  • Different outlet fittings can be supplied separately upon request together with a place for reducer wall mounting .
  • 50mm diameter pressure gauges.
  • Laser markings with technical characteristics as per standard EN ISO 2503.
  • Individual shockproof packaging with internal protection.

MAJORPLUS CO2

CALIBRATION 3/4.8/7 bar

3 pressure calibrations are available in the CO2 version: 3-4.8 and 7 bar. Operating pressure can be adjusted via the safety valve if the reducer is already connected to the gas distribution system in use.

MAJORPLUS NITROGEN

CALIBRATION 4.8 BAR

Majorplus is also available in a version for nitrogen with a high-pressure gauge from 0-400 bar and calibration at 4.8 bar. Ideal for dispensing wine and non-carbonated beverages and perfect for small spaces. Only 1 station version available.

MAJORPLUS SECONDARY

CALIBRATION 3/4.8/7 BAR

Inlet and outlet connections on request. The intermediate secondary pressure reducer feeds a derivation of a dispensing system and is only supplied with a low pressure gauge.

ALWAYS INCLUDED

It is always supplied with a place for reducer wall mounting

ITALY

GASCHIMICAL SYMBOL OUTLET DIMENSIONSSTANDARDREDUCER INLET NUMBER
ArgonArW24.5 x 1/14"8 - UNI 111443
Carbon dioxideCO2W21.7 x 1/14"2 - UNI 111441
NitrogenN2W 21.7 x 1/14"5 - UNI 111442

GERMANY, AUSTRIA, SWITZERLAND, CZECH REPUBLIC, SLOVAKIA, HUNGARY, POLAND

GASCHIMICAL SYMBOL OUTLET DIMENSIONSSTANDARDREDUCER INLET NUMBER
ArgonArW21.8 x 1/14"DIN 477 No.61
Carbon dioxide*CO2W21.8 x 1/14"DIN 477 No.61
NitrogenN2W24.32 x 1/4"DIN 477 No.101

UK

GASCHIMICAL SYMBOL OUTLET DIMENSIONSSTANDARDREDUCER INLET NUMBER
ArgonArG 5/8" BS 341 No.33
Carbon dioxideCO 20.860" x 14 TPIBS 341 No.81
NitrogenN 2G 5/8" BS 341 No.33

FRANCE

GASCHIMICAL SYMBOL OUTLET DIMENSIONSSTANDARDREDUCER INLET NUMBER
ArgonArW 21.7 x 1/14"NF E 29-650/C1
Carbon dioxideCO 2W 21.7 x 1/14"NF E 29-650/C1
NitrogenN 2W 21.7 x 1/14"NF E 29-650/C1

HOLLAND, BELGIUM

GASCHIMICAL SYMBOL OUTLET DIMENSIONSSTANDARDREDUCER INLET NUMBER
ArgonArW 24.32 x 1/14"NEN 3268 RU 31
Carbon dioxideCO2W21.8 x 1/14" NEN 3268 RU 11
NitrogenN2W24.32 x 1/14"NEN 3268 RU 31

SWEDEN, NORWAY, FINLAND

GASCHIMICAL SYMBOL OUTLET DIMENSIONSSTANDARDREDUCER INLET NUMBER
ArgonArW24.32 x 1/14"SS 2238/A1
Carbon dioxideCO 2W21.8 x 1/14"SS 2238/A1
NitrogenN 2W24.32 x 1/14"SS 2238/A1
NitrogenC 3 H 8W21.8 x 1/14" Lh1

SPAIN, PORTUGAL

GASCHIMICAL SYMBOL OUTLET DIMENSIONSSTANDARDREDUCER INLET NUMBER
ArgonArW21.7 x 1/14"MIE AP71
Carbon dioxideCO 2W21.7 x 1/14"MIE AP71
NitrogenN 2W21.7 x 1/14"MIE AP71

U.S.A.

GASCHIMICAL SYMBOL OUTLET DIMENSIONSSTANDARDREDUCER INLET NUMBER
ArgonArCGA 580CGA V-13
Carbon dioxideCO 2CGA 320CGA V-14
NitrogenN 2CGA 580CGA V-13

CHOOSE YOUR PRESSURE REDUCER MAJORPLUS

To fill in the fields below look at the blue codes of the picture

    1

    MODEL OF PRESSURE REDUCER: MAJORPLUS
    2B Lateral connection3B intermediate4B Rear connection

    2

    Kind of Regulation:
    Plastic KobRegularion screw

    3

    Kind of Gas: (Only for 2B)
    CO2ARGONNITROGEN

    4

    No. sampling stations: (Only for 2B)
    12345

    5

    Inlet orientation:
    leftright

    6

    Inlet No. (Not for 3B):
    1i - CYLINDER OUTLET DIMENSION AND COUNTRY2i - CYLINDER OUTLET DIMENSION AND COUNTRY3i - CYLINDER OUTLET DIMENSION AND COUNTRY4i - CYLINDER OUTLET DIMENSION AND COUNTRY
    Inlet type:
    STANDARDMANUAL

    7

    High pressure gauge (only for Nitrogen, not for 3B):
    1G 0-250 bar2G 0-400 bar

    8

    Low pressure gauge

    1st station:3G 0-6 bar R.L. 3 bar4G 0-6 bar R.L. 4.8 bar5G 0-10 bar R.L. 7 bar

    1st station:3G 0-6 bar R.L. 3 bar4G 0-6 bar R.L. 4.8 bar5G 0-10 bar R.L. 7 bar
    2nd station:3G 0-6 bar R.L. 3 bar4G 0-6 bar R.L. 4.8 bar5G 0-10 bar R.L. 7 bar

    1st station:3G 0-6 bar R.L. 3 bar4G 0-6 bar R.L. 4.8 bar5G 0-10 bar R.L. 7 bar
    2nd station:3G 0-6 bar R.L. 3 bar4G 0-6 bar R.L. 4.8 bar5G 0-10 bar R.L. 7 bar
    3rd station:3G 0-6 bar R.L. 3 bar4G 0-6 bar R.L. 4.8 bar5G 0-10 bar R.L. 7 bar

    1st station:3G 0-6 bar R.L. 3 bar4G 0-6 bar R.L. 4.8 bar5G 0-10 bar R.L. 7 bar
    2nd station:3G 0-6 bar R.L. 3 bar4G 0-6 bar R.L. 4.8 bar5G 0-10 bar R.L. 7 bar
    3rd station:3G 0-6 bar R.L. 3 bar4G 0-6 bar R.L. 4.8 bar5G 0-10 bar R.L. 7 bar
    4th station:3G 0-6 bar R.L. 3 bar4G 0-6 bar R.L. 4.8 bar5G 0-10 bar R.L. 7 bar

    1st station:3G 0-6 bar R.L. 3 bar4G 0-6 bar R.L. 4.8 bar5G 0-10 bar R.L. 7 bar
    2nd station:3G 0-6 bar R.L. 3 bar4G 0-6 bar R.L. 4.8 bar5G 0-10 bar R.L. 7 bar
    3rd station:3G 0-6 bar R.L. 3 bar4G 0-6 bar R.L. 4.8 bar5G 0-10 bar R.L. 7 bar
    4th station:3G 0-6 bar R.L. 3 bar4G 0-6 bar R.L. 4.8 bar5G 0-10 bar R.L. 7 bar
    5th station:3G 0-6 bar R.L. 3 bar4G 0-6 bar R.L. 4.8 bar5G 0-10 bar R.L. 7 bar

    9

    Outlet No.
    1o2o3o4o5o6o7o8o9o10o11o

    Pressure reducers with multiple sampling stations are supplied with the same outlet for each station.

    10

    CompanyPersonal